Description

In the configuration without M7, the calculation of the aerosol SAD uses a simple factor to describe swelling for high and low values of relative humidity. A better approach would be to use the aerosol water directly from EQSAM, available in yo(iloop,12). Moreover, the averaging over nitrate and sulfate is not done properly, because radii are averaged instead of volumes.

History

#1 Updated by Philippe Le Sager about 3 years ago

  • Project changed from TM5-ZOOM to TM5-MP
  • Category deleted (Aerosols)